Differences between old and new versions of N2000 chromatography workstation

Differences between the old and new versions of the N2000 chromatography workstation 1. In the use of the old N2000 workstation, the phenomenon that the retention time of the chromatographic peaks are often consistent is often seen by the relevant departments as insufficient resolution of the workstation. The new version of N2000 chromatography workstation (SP1 version) has completely solved this problem.
2. In the use of the old N2000 workstation, the last digit of the peak area is usually "0, 3, 7, 2, 5, 8", some words such as "9" rarely appear, which in turn shows that the integration algorithm of the workstation is Defective. This phenomenon is called "037 phenomenon" by relevant departments. The new version of N2000 chromatography workstation (SP1 version) has completely solved this problem.
3. The old N2000 workstation is not compatible with a small number of new-type laser printers (such as the latest HP and Brother brand). At present, the new version of the N2000 chromatography workstation (SP1 version) no longer has this phenomenon, and the above printers can be used.
4. All the old workstations use plastic shells, so the shielding of external interference signals is insufficient. The new version of the N2000 chromatography workstation (SP1 version) uses an aluminum shell. The anti-interference ability is greatly improved, and the baseline signal-to-noise ratio is stronger.
Fifth, the newly purchased old version of the N2000 workstation does not provide warranty and upgrade services, and the new version of the N2000 chromatography workstation (SP1 version) is purchased and registered online (you can register directly through the website or fax, mail, etc. to send the registration information to me Our company helps to register), we can get our company's N2000 chromatography workstation (SP1 version) hardware warranty for three years, free lifetime software upgrades, even without registration can also get a one-year warranty (except for human factors).
Sixth, the operating habits and interface of the new version N2000 chromatography workstation (SP1 version) and the old version N2000 workstation are kept highly consistent to facilitate the operation of new and old users. Users are welcome to choose the new version of N2000 chromatography workstation (SP1 version). At the same time, our company is also carrying out the trade-in service. You can use any brand model workstation to replace it with a new version of N2000 chromatography workstation (SP1 version). The price is concessional. For details, please log in to me Division designated website or.
Related products: N2000 chromatography workstation (SP1 version) N2000 chromatography workstation

Zhejiang University Zhida Information Engineering Co., Ltd. Hangzhou Saiertai Technology Co., Ltd. Saizhi Technology (Hangzhou) Co., Ltd. End of 2008

Garlic Press

Garlic Press,Alpha Grillers Garlic Press,Orblue Garlic Press,Epicurean Garlic Press

Fortary Industry&Trading Co., Ltd. , https://www.kitchenset.de

Posted on