The inclinometer is an instrument used to measure the apex angle and azimuth of engineering structures such as boreholes, foundation pits, foundation foundations, walls and dam slopes.
?principle
The inclinometer is typically installed in a vertical borehole that passes through the unstable soil layer to the lower stable formation. Use digital vertical motion inclinometer probes, control cables, pulleys and readers to observe the deformation of the inclinometer. The first observation can establish the initial section of the inclined tube displacement. Subsequent observations will show changes in the displacement of the section as the ground surface moves. During the observation, the probe moves from the bottom of the inclinometer to the top, pauses at a half-meter spacing and performs the measurement tilting operation. The tilt of the probe is measured by two force-balanced servo accelerometers. An accelerometer measures the longitudinal position of the inclined tube groove, ie the inclination of the plane of the measuring wheel on the inclinometer probe. Another accelerometer measures the inclination perpendicular to the plane of the wheel. The inclination can be converted into a lateral displacement. Comparing the current and initial observations, the amount of change in the lateral offset can be determined, showing the motion displacement that occurs in the formation. Draw the amount of change in the offset to get a high-resolution displacement profile. This section helps determine the magnitude, depth, direction and velocity of ground motion displacement
After use
Precautions for use of inclinometer
Use in working temperature to prevent vibration, strictly avoid hitting the bottom of the hole, prevent the probe from suddenly accelerating, and prohibit the cable swinging probe;
It is strictly forbidden to use wire and metal when bundling the cable. It is best to use a winch or rope to take the wire;
Wipe the probe in time, clean and dry the joint, lubricate the measuring wheel and o-ring, pay attention to moisture, clean the socket and the panel;
After use, it is strictly forbidden to make each joint not separated for a long time, which will cause moisture to remain in the probe for corrosion for a long time;
After the test is completed, dry the probe and cable, cover the protective cover, and place the probe into the protective case;
Go back indoors, dry the reader and charge the battery;
It is best to let all the joints dry in the room;