(1) As a computer product, the cash register has certain requirements for the external power supply. First, the power supply must have a good grounding, and the grounding resistance is less than 1 Ω. If the power supply is not grounded or the grounding is poor, it may cause the chassis to be charged, which may pose a safety hazard to the operator and affect the stable operation of the cash register.
(2) The grid voltage is 220V/50HZ AC. The allowable fluctuation range of the grid voltage is ±10% of the rated value. Before the equipment is powered on, please check whether the power supply meets the voltage requirements of this product. Only when confirming that the external power supply is normal, You can power on the device.
(3) The neutral line and the fire line of the power supply socket must not be connected incorrectly. The protection ground line of the cash register must not be directly connected to the zero line of the power grid in the equipment room. The ground line must be connected to the absolute ground of the building. .
(4) In order to avoid interference from other electrical equipment to the cash register, the cash register must be separately led out from the power distribution room and cannot share the same line with other high-power equipment, such as: power tools, refrigerators, freezers, electricity. High-power electrical equipment such as heating and air conditioning share one power supply.
(5) In order to avoid sudden interruption of power supply, fluctuation of grid voltage, and interference of instantaneous spikes, a suitable uninterruptible power supply (UPS) should be selected as needed. However, the protection ground of the UPS power supply should be connected.
(6) When turning on the power, first turn on the power switch of the external device, then turn on the power of the host. When shutting down, you should first turn off the power of the host and then turn off the power of the external device.
(7) Since most of the cash register products use ATX power supply, the power supply of the main engine is not completely turned off when the power is turned off. If it is ensured that the power supply is disconnected, the outlet switch should be disconnected or the power plug should be unplugged, especially in thunderstorms. It may cause lightning strikes on the device.
(8) In order to reduce the interference of the power supply on the data signal, the power cable and the data cable (display, network cable, printer data cable, serial communication cable) should be kept at a distance of more than 100 MM at the time of installation, and the power cable and data cable must not be allowed. Wrapped together.